B.47 SYSTem:COMMunicate:LAN:TELnet:PORT?

QUERY

SYST:COMM:LAN:TEL:PORT?

Syntax:

Short Form: SYST:COMM:LAN:TEL:PORT?
Long Form: SYSTem:COMMunicate:LAN:TELnet:PORT?

Description:

Indicates port assigned for Telnet communication via the LAN interface.

Return Format: in text format, a number from 0 to 65535
Example:

SYST:COMM:LAN:TEL:PORT? returns 8003 to indicate port 8083 is assigned to be used during
Telnet sessions.

B.48 SYSTem:ERRor?

QUERY

SYST:ERR?

Syntax:

Short Form: SYST:ERR?

Long Form: SYSTem:ERRor?

Description:

Returns error codes and messages.

Return Format: is text format in -XXX XXXXXXXXXXXXX
Example:

Input command S0URce:VOLTage 2w will cause error. SYSTem:ERR? returns error code “-138,”
and sending SYSTem:ERR? again returns no error code “+0,”. Refer to Table for a complete list of
error codes.

TABLE B-2. ERROR CODES

Error Code

Explanation

0,“No error”

No error

72, “OVP”

Overvoltage protection error:
a. The output voltage is exceeding the OVP value.
b. The Analog Programming input for output voltage setting is too high (higher then
OVP value).

73, “OCP”

Hardware overcurrent protection error: Output current exceeds 110% of rated current,
this OCP value is restricted by hardware and not adjustable.

74, “REMOTE SENSE OVER”

The max. compensation voltage is 5V d-c (the sum of two wires, i.e. 2.5V d-c for each).

75, ““D2D Module 1 fault”

The DC to DC converter module number 1 is failed. There is only one DC to DC mod-
ule in KLN 750W models.

76, ““D2D Module 2 fault”

Not applicable

77, “Analog shut-off shutdown”

a. The slave unit(s) failed when operate in parallel/series.
b. The Pin 23 and Pin 24 of the Analog Programming Port are shorted to shut-off the
output.

78, “Software OCP”

Software over current protection error: The output current exceeds the set OCP value
(adjustable manually or remotely) for more than 1 second.

79, “AC Fault“

Ac line input abnormal

83, “FAN failed”

One or more fan failed.

84, “D2D Module 3 fault”

Not applicable

85, “D2D Module 4 fault”

Not applicable

-102, “Syntax error”

An unrecognized command or data type was encountered; for example, a string was
received when the device does not accept strings.

-104, “Data type error”

The parser recognized a data element different than one allowed; for example, numeric
or string data was expected but block data was encountered.

-109, “Missing parameter”

Fewer parameters were received than required for the header; for example, the
SYST:BEEP command requires one parameter, so SYST:BEEP is not allowed, while
SYST:BEEP ON is allowed.

-221, “Settings confect”

Indicates that a legal program data element was parsed but could not be executed due
to the current device state