beautypg.com

B.16 source:list:rtime command, B.17 source:list:rtime? query, B.18 source:memory:cls command – KEPCO KLN 750W Series, Firmware Version 1.60 to 1.6x User Manual

Page 78: B.19 source:memory:current:x command, B.20 source:memory:current:x? query, B.21 source:memory:list:x? query, B.22 source:memory:recall:x command, B.16, Sour, B.17

background image

B-4

KLN 750W 032614

B.16 SOURce:LIST:RTIMe COMMAND

SOUR:LIST:RTIM

Syntax:

Short Form: SOUR:LIST:RTIM Long Form: SOURce:LIST:RTIMe

Description:

Sets the output ramp-up time.

Argument:

is a value in the range from 0.0 to 9.9 seconds.

Example:

SOURce:LIST:RTIMe 3.0 programs the output ramp-up time to 3.0 seconds.

B.17 SOURce:LIST:RTIMe?

QUERY

SOUR:LIST:RTIM?

Syntax:

Short Form: SOUR:LIST:RTIM?

Long Form: SOURce:LIST:RTIMe?

Description:

Indicates (in seconds) how long output voltage takes to reach programmed value.

Return Format:
Example:

SOURce:LIST:RTIMe? returns 3.00000E+00 to indicate ramp-up time is 3.0 seconds.

B.18 SOURce:MEMory:CLS COMMAND

SOUR:MEM:CLS

Syntax:

Short Form: SOUR:MEM:CLS Long

Form:

SOURce:MEMory:CLS

Description:

Clears all memory locations used for storing and recalling power supply settings.

Argument:

None

Example:

SOURce:MEMory:CLS clears all memory locations.

B.19 SOURce:MEMory:CURRent:X COMMAND

SOUR:MEM:CURR:X

Syntax:

Short Form: SOUR:MEM:CURR:X Long Form: SOURce:MEMory:CURRent:X

Description:

Sets the memory location defined by X to the current value .

Argument:

is a value in the range from 0 to rated current of unit.

Example:

SOURce:MEMory:CURRent:5 11.6 sets memory location 5 to 11.6A.

B.20 SOURce:MEMory:CURRent:X?

QUERY

SOUR:MEM:CURR:X?

Syntax:

Short Form: SOUR:MEM:CURR:X? Long Form: SOURce:MEMory:CURRent:X?

Description:

Returns current value stored in memory location X (in amperes).

Return Format:
Example:

SOURce:MEMory:CURRent:5? returns 11.6 (Voltage stored in memory location 3 is 11.6A).

B.21 SOURce:MEMory:LIST:X?

QUERY

SOUR:MEM:LIST:X?

Syntax:

Short Form: SOUR:MEM:LIST:X?

Long Form: SOURce:MEMory:LIST:X?

Description:

For the memory location defined by X, returns voltage (Volts) and current (Amperes) in sci-
entific notation.

Return Format:
Example:

SOURce:MEMory:LIST:3? returns 5.00000E+02, 2.50000E-00 (Voltage/Current stored in memory
location 3 is 50V, 2.5A).

B.22 SOURce:MEMory:RECall:X COMMAND

SOUR:MEM:REC:X

Syntax:

Short Form: SOUR:MEM:REC:X

Long Form: SOURce:MEMory:RECall:X

Description:

Restores power supply settings to the voltage and current values stored in memory loca-
tion defined by X.
If the output is off, the recalled voltage and current set values are shown on the
front panel Voltage and Current displays. If the output is on, the output changes to the recalled
voltage and current values which are also shown on the front panel Voltage and Current displays.

Argument:

X is a number from 0 to 15 representing one of 16 memory locations

Example:

SOURce:MEMory:RECall:3 sets power supply setpoints to 50V and 2.5A (values previously
stored via either front panel or SOURce:MEMory:VOLTage:X and SOURce:MEMory:CURRent:X
commands). If output is on, output is changed to 50V, 2.5A. If output is off, set values of 50V and
2.5A are displayed on the front panel.