Appendix b - scpi command/query definitions, B.1 introduction, Table b-1. scpi subsystem command/query index – KEPCO KLN 750W Series, Firmware Version 1.60 to 1.6x User Manual

Page 75: B.2 numerical values, B.3 disp:contrast command, B.4 disp:contrast? query, Disp:cont

background image

KLN 750W 032614

B-1

APPENDIX B - SCPI COMMAND/QUERY DEFINITIONS

B.1

INTRODUCTION

This appendix defines the SCPI subsystem commands and queries used with the KLN 750W power
supply. Subsystem commands are defined in PAR. B.3 through B.51. Table B-1 provides a quick
reference of all SCPI subsystem commands and queries used in the KLN 750W.

B.2

NUMERICAL VALUES

Refers to integer

Refers to Floating (scientific notation: digits with decimal point and Exponent, e.g., 2.71E1 for 27.1.)

B.3

DISP:CONTrast COMMAND

DISP:CONT

Syntax:

Short Form: DISP:CONT

Long Form: DISPlay:CONTrast

Description:

Sets the brightness of front panel Voltage and Current displays.

Argument:

is a value in the range from 0 to 5.

Example:

DISPlay:CONTrast 3 sets display contrast to level 3.

B.4

DISP:CONTrast? QUERY

DISP:CONT?

Syntax:

Short Form: DISP:CONT?

Long Form: DISPlay:CONTrast

Description:

Returns the brightness level set by DISP:CONT.

Return Format:

TABLE B-1. SCPI SUBSYSTEM COMMAND/QUERY INDEX

COMMAND

PAR.

COMMAND

PAR.

DISP:CONT, ?

B.3, B.4

SOUR:VOLT:PROT:LEV, ?

B.29, B.30

FETC?

B.5

SYST:BEEP, ?

B.31, B.32

OUTP, ?

B.6, B.7

SYST:COMM:LAN:DHCP, ?

B.33, B.34

OUTP:PON, ?

B.8, B.9

SYST:COMM:LAN:GATE, ?

B.35, B.36

SOUR:CURR, ?

B.10, B.11

SYST:COMM:LAN:IP, ?

B.37, B.38

SOUR:CURR:PROT:LEV, ?

B.12, B.13

SYST:COMM:LAN:IPAD, ?

B.39, B.40

SOUR:LIST:DTIM, ?

B.14, B.15

SYST:COMM:LAN:MAC, ?

B.41, B.42

SOUR:LIST:RTIM, ?

B.16, B.17

SYST:COMM:LAN:RES

B.43

SOUR:MEM:CLS

B.18

SYST:COMM:LAN:SMAS, ?

B.44, B.45

SOUR:MEM:CURR:X, ?

B.19, B.20

SYST:COMM:LAN:TEL:PORT, ?

B.46, B.47

SOUR:MEM:LIST:X?

B.21

SYST:ERR?

B.48

SOUR:MEM:REC:X, ?

B.22, B.23

SYST:KLOC, ?

B.49, B.50

SOUR:MEM:VOLT:X, ?

B.23, B.24

SYST:LOC

B.51

SOUR:VOLT, ?

B.25, B.26

SYST:REM

B.52

SOUR:VOLT:LIM:LOW, ?

B.27, B.28

SYST:VERS?

B.51

NOTE: Commands listed above that are followed by “, ?“ have a related query.