beautypg.com

14 display brightness, 15 i/o select, 16 rs-485 baud rate – KEPCO KLN 750W Series, Firmware Version 1.60 to 1.6x User Manual

Page 47: Display brightness -11, I/o select -11, Rs-485 baud rate -11, Ar. 3.3.14, R. 3.3.15, R. 3.3.16

background image

KLN 750W 032614

3-11

3.3.14

DISPLAY BRIGHTNESS

The brightness level for the Voltage and Current displays can be set from 0 (dimmest) to 5
(brightest).

1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display

shows

(BRIT) to access BRIGHTNESS setting.

2. Press ENTER key to view setting

Brightness level (0, 1, 2, 3, 4 or 5) displayed in Current display, e.g.,

(3).

3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.

3.3.15

I/O SELECT

Used to select either RS-485 (standard) or optional GPIB or LAN interfaces for remote digital
control.

1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display

shows

(I.O) to access I/O SELECT setting.

2. Press ENTER key to view setting.

RS-485 mode displayed as

(485) in Current display.

GPIB mode displayed as

GPIB) in Current display if GPIB interface installed.

LAN mode displayed as

LAN) in Current display if LAN interface installed.

3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.

3.3.16

RS-485 BAUD RATE

Used to select baud rate for RS-485 communication. Default setting is 19.2K

1. Enter the menu (see PAR. 3.2.2 and Table 3-3) and rotate the encoder until Voltage display

shows

(485) to access RS-485 BAUD RATE setting.

2. Press ENTER key to view setting.

4800 baud rate displayed as

(4.8K) in Current display.

9600 baud rate displayed as

(9.6K) in Current display.

19200 baud rate displayed as

(19.2K) in Current display.

38400 baud rate displayed as

(38.4K) in Current display.

57600 baud rate displayed as

(57.6K) in Current display.

115200 baud rate displayed as

(115K) in Current display.

3. Rotate encoder until Current display shows desired setting, then press ENTER to confirm.