TABLE 3-1. FRONT PANEL CONTROLS AND INDICATORS

NUMBER

(FIGURE 3-1)

CONTROL/INDICATOR

FUNCTION

1

POWER ON/OFF

circuit breaker A7CB1

Applies source power to unit

2

REMOTE

status LED

Green LED, lights when unit is under remote control. Press SHIFT/LOCAL key to
restore local control.

3

ALARM

status LED

Red LED, lights if OVP, OCP or OTP are triggered or there is a command error, front
panel operation error, or power supply failure. Refer to Table B-2 for an explanation of
error codes.

4

KEYLOCK

status LED

Yellow LED, lights when front panel keys are locked. To lock the front panel keys and
encoder, press SHIFT and tap the encoder. Repeat to unlock the front panel.

5

SHIFT

status LED

Blue LED, lights when SHIFT mode is active.

6

Encoder

The encoder Increases (clockwise) or decreases (counterclockwise) the highlighted
digit of the Voltage or Current display, then press ENTER key to confirm. Tap the
encoder

to change the highlight. The highlighted digit blinks slowly.

7

Output ON/OFF

status LED

Green LED, lights when output is on.

8

OUT on/off

key

Output ON/OFF enable/disable. The DC power output will be set to OFF automati-
cally in the following situations:
a. Restart of the AC input. (See PAR. 3.3.9 to configure whether unit powers up with
out off at previous setting.)
b. The mains supply is interrupted for more than 100mS.
c. The mains supply exceeds or is under the rated input range more than 500ms.
d. If OCP - OVP - OTP are detected.
e. When a user is operating the Menu function on the front panel.

9

ENTER/MENU

dual function key

a. Press ENTER to confirm value set by encoder.
b. Press SHIFT+ENTER to get access to MENU function. See PAR. 3.2.2
c. When output is ON, the access to the Menu will be denied.
d. The OUT on/off key will be disabled while using the Menu function.

10

RCL/STO

dual function key

A maximum of 16 memory settings can be stored or recalled. See PAR’s. 3.3.6 and
3.3.7 for de
tails.
a. Press RCL as many times as needed to view the stored voltage/current settings in
sequence, press ENTER to confirm recall, press V to exit recall function.
b. Press SHIFT + STO to store settings. Rotate encoder to scroll through memory
cells. Press ENTER to store programmed voltage and current settings, press ENTER
to exit storage function.

11

SHIFT/LOCAL

dual function key

When unit is operated manually in local mode, this key functions as a SHIFT key.
When blue

LED is ON, the functions noted in blue text for the front panel keys can

accessed when SHIFT is pressed.
b. When the unit is remote controlled, press this key to exit remote control and restore
local front panel operation.

12

A/OCP

dual function key

a. Press A/OCP key to adjust the A set current value: the last digit of the Current dis-
play will be blinking. Turn the encoder to adjust the value of the blinking digit, then
press ENTER to confirm. A cannot be set more than programmed value of OCP. Tap
the encoder to go to the next digit.
b. To set OCP press SHIFT key, then press A/OCP key. Use encoder and ENTER to
set OCP. OCP cannot be set less than programmed value of A.
c. Press ENTER key to exit A set or OCP set mode.

13

V/OVP

dual function key

a. Press V/OVP key to adjust the V set voltage value: the last digit of the Voltage dis-
play will be blinking. Turn the encoder to adjust the value of the blinking digit, then
press ENTER to confirm. V cannot be set more than programmed value of OVP. Tap
the encoder to go to the next digit.
b. To set OVP press SHIFT key, then press V/OVP key. Use encoder and ENTER to
set OVP. OVP cannot be set less than programmed value of V.
c. Press ENTER key to exit V set or OVP set mode.

14

OCP indicator

Overcurrent Protection indicator. Lights if overcurrent has occurred. Blinks while set-
ting overcurrent protection.