KLN 750W 032614

3-25

3.6.1

RS-485 OPERATION

See PAR. 2.7.2 for RS-485 connections.

See PAR. 3.3.18 to change the RS-485 Address.

See PAR. 3.3.16 to change the RS-485 Baud Rate.

3.6.2

GPIB OPERATION (IF OPTION INSTALLED)

See PAR. 2.7.3 for GPIB connections.

See PAR. 3.3.17 to change the GPIB Address.

3.6.2.1

IEEE 488 (GPIB) BUS PROTOCOL

Table 3-4 defines the interface capabilities of the KLN 750W power supply (Talker/Listener) rela-
tive to the IEEE 488 (GPIB) bus (reference document ANSI/IEEE Std 488: IEEE Standard Digital
Interface for Programmable Instrumentation
) communicating with a Host Computer—Controller
(Talker/Listener). Tables 3-5 and 3-6 define the messages sent by the KLN 750W, or received
by the KLN 750W, via the IEEE 488 bus in IEEE 488 command mode and IEEE 488 data mode,
respectively. These messages are enabled during the “handshake” cycle, with the KLN 750W
power supply operating as either a Talker or a Listener. (See PAR. 3.6.3.1 to change the GPIB
address.

TABLE 3-4. IEEE 488 (GPIB) BUS INTERFACE FUNCTIONS

FUNCTION

SUBSET

SYMBOL

COMMENTS

Source Handshake

SH1

Complete Capability (Interface can receive multiline messages)

Acceptor Handshake

AH1

Complete Capability (Interface can receive multiline messages)

Talker

T6

Basic talker, serial poll, unaddress if MLA (My Listen Address) (one-byte address)

Listener

L4

Basic listener, unaddress if MTA (My Talk Address) (one-byte address).

Service Request

SR0

No Capability.

Remote/Local

RL1

Complete capability. Interface selects either local or remote information. In local
mode the KLN 750W executes front panel commands, but can be set to remote
mode via IEEE 488 bus. When in Remote mode all front panel keys are disabled
except LOCAL function key.

Parallel Poll

PP0

No Capability

Device Clear

DC1

Complete Capability. KLN 750W accepts DCL (Device Clear) and SDC (Selected
Device Clear).

Device Trigger

DT0

No Capability

Controller

C0

No Capability