B.29 SOURce:VOLTage:PROTection:LEVel COMMAND

SOUR:VOLT:PROT:LEV

Syntax:

Short Form: SOUR:VOLT:PROT:LEV { MIN | MAX }
Long Form: SOURce:VOLTage:PROtection:LEVel { MIN | MAX }

Argument:

is a value in the range from 0% to 110% of rated voltage.
MIN is the value programmed for output voltage (SOUR:VOLT)
MAX is 110% of rated voltage of unit

Description:

Sets the overvoltage protection (OVP) value (in volts). OVP values set using this command
are in effect once the unit is returned to local operation. SOUR:VOLT:PROT:LEV MAX sets OVP to
maximum value: 110% of rated voltage. SOUR:VOLT:PROT:LEV MIN sets OVP to the same value
as programmed voltage (SOUR:VOLT). *RST sets SOUR:VOLT:PROT:LEV to maximum value.

Example:

SOURce:VOLTage:PROtection:LEVel 36 sets the overvoltage protection level to 36V. This is the
maximum overvoltage protection value if the unit is a 30V model. SOUR:VOLT:PROT:LEV MIN
sets OVP to the same value programmed for output voltage (SOUR:VOLT).

B.30 SOURce:VOLTage:PROTection:LEVel?

QUERY

SOUR:VOLT:PROT:LEV?

Syntax:

Short Form: SOUR:VOLT:PROT:LEV? Long Form: SOURce:VOLTage:PROtection:LEVel?

Description:

Indicates programmed lower limit for output voltage (in volts).

Return Format:
Example:

SOURce:VOLTage:PROtection:LEVel? returns 4.40000E+01 to indicate overvoltage protection
level is programmed to 44V.

B.31 SYSTem:BEEP COMMAND

SYST:BEEP

Syntax:

Short Form: SYST:BEEP { ON | OFF | 1 | 0 }
Long Form: SYSTem:BEEP { ON | OFF | 1 | 0 }

Description:

Sets the audible beep each time a front panel key is pressed to on or off.

Argument:

or 1 enables audible beep
or 0 disables audible beep

Example:

SYSTem:BEEP 1 turns on the audible beep.

B.32 SYSTem:BEEP?

QUERY

SYST:BEEP?

Syntax:

Short Form: SYST:BEEP?

Long Form: SYSTem:BEEP?

Description:

Indicates whether audible beep is on or off. Returns 1 to indicate the beep is on, 0 to indicate
beep is off.

Return Format: { 1 | 0 }
Example:

SYSTem:BEEP? returns 1 (audible beep is enabled).

B.33 SYSTem:COMMunicate:LAN:DHCP COMMAND

SYST:COMM:LAN:DHCP

Syntax:

Short Form: SYST:COMM:LAN:DHCP { ON | OFF | 1 | 0 }
Long Form: SYSTem:COMMunicate:LAN:DHCP { ON | OFF | 1 | 0 }

Description:

Allows the IP address to either be assigned from the DHCP server (on) or assigned manu-
ally (static IP Address) by the user (off).

Argument:

or 1 enables DHCP
or 0 disables DHCP

Example:

SYST:COMM:LAN:DHCP ON assigns the DHCP server to assign the IP address.

B.34 SYSTem:COMMunicate:LAN:DHCP?

QUERY

SYST:COMM:LAN:DHCP?

Syntax:

Short Form: SYST:COMM:LAN:DHCP? Long Form: SYSTem:COMMunicate:LAN:DHCP?

Description:

Indicates whether DHCP is on (enabled) or off (disabled). Returns 1 to indicate the DHCP is
on, 0 to indicate DHCP is off.

Return Format: { 1 | 0 }
Example:

SYST:COMM:LAN:DHCP? returns 1 (DHCP is enabled).