2-9

FIGURE 2-5. LOAD CONNECTION TERMINALS FOR 6V - 150V MODELS

Kepco strongly recommends the use of stranded (not solid) wire with (+) and (–) wires tightly
twisted to reduce self-inductance; wire end ferrules are suggested to prevent fraying of the
strands.

NOTE

REGARDLESS OF OUTPUT CONFIGURATION, EITHER LOCAL OR REMOTE OUT-
PUT SENSE LINES SHOULD BE CONNECTED FOR OPTIMUM OPERATION.

• OBSERVE POLARITIES: The +S sensing wire must be connected to the (+) load wire,

and the –S sensing wire must be connected to the (–) load wire.

• IF LOCAL SENSING IS USED: Install red and black sense leads supplied (see Figure 2-

6).

2.5.6

LOAD CONNECTION USING LOCAL SENSING

Figure 2-6 shows a typical configuration using local sensing. Local sensing is recommended for
a high noise or switching mode load such as d-c to d-c or d-c to a-c.

CAUTION: CONNECT +S ONLY TO + AND –S ONLY TO –. CONNECTING +S TO –S, +V

TO –S, OR –V TO +S WILL DAMAGE THE UNIT.

FIGURE 2-6. LOAD CONNECTIONS, LOCAL SENSING