Page 65: Hyper terminal ascii setup -29

background image

KLN 750W 032614

3-29

a. If a Message box opens that says “Unable to Connect to 192.168.0.100 port 8003” click

OK, then click File - Properties at the top menu bar of the HyperTerminal window to
open the Properties Dialog Box (Figure 3-8).

FIGURE 3-8. HYPER TERMINAL PROPERTIES

b. Click the Settings tab, then click ASCII setup (see Figure 3-9).

FIGURE 3-9. HYPER TERMINAL ASCII SETUP

c.

Check the “Send line ends with line feeds” and “Echo typed characters locally” boxes.

6. Repeat steps 4 and 5, then, from the computer via the blank HyperTerminal screen, send

syst:rem and ENTER. The green remote

LED at the KLN front panel goes on.

7. Send *idn? query to verify unit is operating properly via the LAN interface. A typical

response for a successful LAN connection is:

KEPCO,KLN 20-38E,500354,01.60