(1) Sensor Connection

Connect to the input port of the terminal block.

Each input terminal may be connected regardless of the channel number.

Sensor types include Normal Close (NC) and Normal Open (NO). For more
information on setup by sensor type, refer to {Data Setup} {Event Setup}
{Sensor}
.
Normal Close (NC): Normally closed; opens when a signal is received
Normal Open (NO): Normally open; closes when a signal is received


(2) Relay Connection

Outputs alarm signals to external devices such as LED and siren by relaying them to

these external devices

Connect the external alarm device to the COM or Out port of the sensor/relay terminal

block.

Relay types include Normal Close (NC) and Normal Open (NO). For more
information on setup by sensor type, refer to {Data Setup} {Event Setup}
{Sensor}
.
Normal Close (NC)
: Normally closed; opens when a signal is received
Normal Open (NO): Normally open; closes when a signal is received