Comm ands - 4
AOT
Process Statement
SYNTAX:
AOT channel,value
PURPOSE:
To wr ite data to a analo g output por t.
REMARK S:
AOT causes the an alog output voltag e to move to a level specified by the value. The voltag e will
remain constant until another AOT statement is executed. The analog output ICs change voltage as
fast as the CPU can wr ite to them. See your hardw are manual for m ore information.
RELATED:
CONFIG AOT
EXAMPLE:
See your hardw are m anual.
ERROR:
< Data negative> – for channel and value
< Data out of range> – if channel too large
< Command not available> – if card does not have hardware support