CON FIG C ommands - 2
CONFIG BAUD
Statement
SYNTAX:
C O N F I G BA U D port,baud rate, mode, parity [,com]
PURPOSE:
To change the ser ial port param eters.
REMARK S:
The powe r– up default for C OM1 is:
19,200 baud
8 data bits and 2 sto p bits
no parity
The powe r– up default for C OM2 is:
19,200 baud
8 data bits and 1 sto p bit
no parity
RS-232
All these par ameter s are pr ogram mable. Once pr ogram med, the serial pa ram eters w ill rema in in
place even when the p rogr am stops. A rese t or anothe r pow er– up will cause the default value s to
be reinstalled.
port is the COM por t number. COM 1 is 1, CO M2 is 2.
The baud rate parameter is a number from 0 to 7 or 8 which correspond to the baud rates below:
0
150
4
2400
8
38,400 (RP C-2350 only)
1
300
5
4800
2
600
6
9600
3
1200
7
19,200
The mode par ameter determ ines the data word length, whether par ity is checked, and the number of
stop bits.
0
7 data, no parity, 1 stop
4
8 data, no parity, 1 stop
1
7 data, no parity, 2 stop
5
8 data, no parity, 2 stop
2
7 data, parity, 1 stop
6
8 data, parity, 1 stop
3
7 data, parity, 2 stop
7
8 data, parity, 2 stop
The parity parameter deter mines the type of parity. Specifying a “0” is even parity and specifying
“1” is odd parity. If the mode param eter is set for no parity, then enter a “ 0”.
com is an optional parameter and is valid only for COM2 on boar ds with a RS-422/485 port. It
determ ines if this port is R S-232, RS-422, or RS-4 85. When in R S-485 mo de, the output is
automatically turn on when printing and turn off when it is finished. The tr ansmitter is turned off