Config ain – Remote Processing CAMBASIC User Manual
Page 174

CON FIG C ommands - 1
CONFIG AIN
Statement
SYNTAX:
C O N F I G A IN channel, input, range
W h e re : channel is 0 to range of inputs for your card.
input specified single ended or differential if supported on your card
range is voltage input, if supported on your card
PURPOSE:
Initialize analog in puts
REMARK S:
Refer to your hardwar e manual for power– up defaults, input and range parameters, if any. The
RPC -2300 is not con figured w hile the RP C-2350 is configur ed for 0-5 V, single ended fo r all
channels.
RELATED:
none
EXAMPLE:
10 CONFIG AIN 0,0,1
Configures channel 0 for differential mode, 0 to + 5V, on the RP C-2350
ERROR:
<
Data negative
>
– all parameters
<
Data out of range
>
– if illegal parameters