Pulse – Remote Processing CAMBASIC User Manual
Page 134

Comm ands - 101
PULSE
Process Function
SYNTAX:
n= PULSE(m)
PURPOSE:
To re turn the r emaining time of a pu lsed output.
REMARK S:
The resolution of the software pulse timers is 0.005 seconds (0.01 sec in 9 M hz systems). The
remaining time is returned in seconds. A time of 0 indicates the PULSE comm and finished.
The argument range for m is 0 to 7, which is the pulse number set by the PULSE command.
See the Multitasking Chapter for more information.
RELATED:
CLE AR PU LSE, PUL SE comm and
EXAMPLE:
10 A=PULSE(2)
ERROR:
< Data negative> – for m
< Illegal argument> – if m > 7