beautypg.com

Quick user interface reference – Precision Digital PD6830 User Manual

Page 98

background image

PD6830 Pulse Input Rate/Totalizer Instruction

Manual

98

QUICK USER INTERFACE REFERENCE

Pushbutton

Function

Menu

Go to Programming mode, back out one level of programming.
Hold to enter Advanced Features mode. Leave grand to-
tal/max/min mode.

Right Arrow

Move to next digit or decimal point position. Go to reset menu
Return to last programming menu.

Up Arrow

Move to next selection or increment digit.
Enter grand total/max/min display mode.

Enter

Accept selection/value and move to next selection.

Acknowledge Alarm.

Cycle Rate, Total, Grand Total, and Max/Min on Lower Display
While in Run Mode, pressing Display will cycle the rate, total, grand total, and
max/min display. In this mode, the display will show the rate, total, grand total,
maximum, or minimum values since last reset when they are not selected as the
top or bottom display. The grand total, max, or min will display for 10 seconds.
Press Enter while displaying the rate, total, grand total, max, or min, to disable the
10 second time-out and continuously display the rate, total, grand total, max, or
min. Press Enter again to disable this display lock.

Menu

for

3 seconds

Operational Modes

Menu
Hold

Menu

Display

Rate, Total,

Grand Total,

Max & Min

Menu Hold

Program

Run

Advanced

Features