PD6830 Pulse Input Rate/Totalizer Instruction

Manual

11

Rate/Totalizer

DISPLAY
ASSIGNMENT

The Top display is assigned to rate or total. The Bottom
display is programmable to display total; total and units; total
and tag; total, total units, and rate units; grand total; grand total
and grand total units; grand total and tag; grand total, grand
total units, and rate units; rate units; rate; rate and total units;
rate and rate units; rate and tag; rate units; total units; a
custom tag; or be off (blank).

RATE DISPLAY
UNITS

Gallons, liters, imperial gallons, cubic meters, barrels, bushels,
cubic yards, cubic feet, cubic inches, liquid barrels, beer
barrels, hectoliters, or custom.

RATE DISPLAY
TIME BASE

Rate display may be calculated in terms of units per second,
minute, hour, or day.

TOTAL & GRAND
TOTAL DISPLAY
UNITS

Gallons, liters, imperial gallons, cubic meters, barrels, bushels,
cubic yards, cubic feet, cubic inches, liquid barrels, beer
barrels, hectoliters, or custom. Setting is independent for each.

TOTAL & GRAND
TOTAL DISPLAY
UNIT MULTIPLIER

x1, x100 (h), x1000 (k), or x1,000,000 (M) multiplier (and
prefix) applied to total or grand total display units. Setting is
independent for each.

TOTAL & GRAND
TOTAL DECIMAL
POINT

Up to six decimal places or none:

6.666666

, 55.55555, 444.4444, 3333.333, 22222.22,

111111.1

or

0000000

Total and grand total decimal points are independently pro-
grammed, and are independent of rate decimal point.

TOTALIZERS

Calculates total and grand total based on rate and field pro-
grammable multiplier to display total in engineering units. Time
base must be selected according to the time units in which the
rate is displayed. The total and grand total utilize the same
time base, with different conversion factors and resets.

TOTALIZER
RESET

Via SafeTouch

®

RESET button, mechanical button (cover off),

external contact closure (total only), automatically via user se-
lectable preset value and time delay (1 – 99,999 sec). Manual
reset may be disabled or protected by password for the total
and grand total. Total and grand total reset independently.