beautypg.com

5 replacing the ground fuse – KACO Powador 16.0 TR3 User Manual

Page 42

background image

M a i n t e n a n c e / T r o u b l e s h o o t i n g

Operating Instructions Powador 16.0 TR3, 18.0 TR3_EN

Page 43

Installing the fan

↻ You have removed the defective fan.

 Replace the fan only with a fan recom-

mended by KACO. Ask KACO Service if
necessary.

 Attach the rubber collar to the replacement

fan (fi gure 16 on page 43).

 Ensure that the rubber collar is correctly

seated.

1.

Insert the replacement fan into the fan
holding fi xture (fi gure 17 on page 43).

2. Move the fan to the side until it locks into

the fan holding fi xture.

3. Plug in the fan plug.

4. Place the side housing cover on the unit.

5. Fasten the side housing cover to the unit

with the Torx screws.

6. Check that the fi ttings are secure and that

the terminals are well seated.

»

The replacement fan is ready for operation.

7.

Switch on inverter as described in section
7.4 on page 27.

Fig. 16:

Rubber collar

Fig. 17:

Replacing the fan

9.5

Replacing the ground fuse

Replacing the ground fuse

1.

Open the connection area (see section 7.1 on page 19).

2. Ensure complete disconnection on the AC and DC sides.

3. Remove defective fuse from fuse holder.

4. Insert the replacement fuse into the fuse holder.

5. Close the connection area (see section 7.4 on page 27).

»

The fuse has been replaced.

6. Switch on the inverter (see section 7.5 on page 27).