KACO Powador 16.0 TR3 User Manual
Page 38

C o n f i g u r a t i o n a n d O p e r a t i o n
Operating Instructions Powador 16.0 TR3, 18.0 TR3_EN
Page 39
8.4.2.2 Using the web server
To avoid problems with incompatibility, use the most recent version of your Internet browser.
NOTICE
You can also access the web server of the inverter via the Internet. To do this, additional settings of
your network confi guration, particularly your Internet router, are required.
Note that communication with the inverter is carried out over an unsecured connection, particularly
in the case of a connection over the Internet.
Calling up the web server
↻ Confi gure the Ethernet interface.
↻ Connect the Ethernet interface.
1.
Open an Internet browser.
2. In the address fi eld of the Internet browser, enter the IP address of the inverter and open the site.
»
The Internet browser displays the start screen of the web server.
After it has opened, the web server displays information about the inverter as well as the current yield data.
The web server supports the display of the following measurement data and yield data:
•
Feed-in power
•
Generator power
•
Status
•
Generator voltage
•
Grid power
•
Unit temperature
•
Grid voltage
In order to display and export yield data, proceed as follows:
Select the display period
1.
Call up the web server.
2. Select the display period by choosing one of the buttons: day view, month view, year view or overall view.
Filtering display data (day view only)
1.
Open the web server.
2. Select the day view.
3. To show or hide measured values, select or deselect the corresponding checkboxes in the “Select display”
area.
Exporting data
1.
Filter the display data if necessary.
2. Select the display period if applicable (day, month, year or overall view).
3. Click the “Export data” button.
4. Save the fi le.
NOTICE
Regardless of the display data selected in the “Select display” area, an export fi le always contains all
measurement data and yield data available for the selected period.