T e c h n i c a l D a t a
Operating Instructions Powador 16.0 TR3, 18.0 TR3_EN
Page 13
4 Technical
Data
4.1 Electrical
data
Input Levels
16.0 TR3
18.0 TR3
Max. PV generator power [W]
16,000
18,000
DC MPP range from [V] to [V]
200 to 510
Minimum DC voltage [V]
200
Number of strings
9
Number of MPP controls
3
Polarity safeguard
Short-circuit diode
DC overvoltage category
OVCII
Output Levels
Rated power [VA]
13,500
15,000
Max. power [VA]
13,500
15,000
Grid voltage [V]
230/400
Rated current [A]
3 x 19.5
3 x 21.7
Max. current [A]
3 x 19.5
3 x 21.7
Rated frequency [Hz]
50/60
cos phi
0.80 inductive to 0.80 capacitive
Number of feed-in phases
3
Distortion factor [%]
<3
AC overvoltage category
OVCIII
General electrical data
Max. effi
ciency [%]
96.2
European effi
ciency [%]
95.6
Internal consumption: standby [W]
< 10
Internal consumption: night [W]
1.9
Feed-in starts at [W]
180
Circuit design
Self-commutated, galvanically isolated, RF transformer
Transformer unit
Yes
Grid monitoring
Country-specifi c
CE conformity
Yes
Clock frequency [kHz]
17
Table 1:
Electrical data