beautypg.com

4 technical data, 1 electrical data – KACO Powador 16.0 TR3 User Manual

Page 12

background image

T e c h n i c a l D a t a

Operating Instructions Powador 16.0 TR3, 18.0 TR3_EN

Page 13

4 Technical

Data

4.1 Electrical

data

Input Levels

16.0 TR3

18.0 TR3

Max. PV generator power [W]

16,000

18,000

DC MPP range from [V] to [V]

200 to 510

Minimum DC voltage [V]

200

Number of strings

9

Number of MPP controls

3

Polarity safeguard

Short-circuit diode

DC overvoltage category

OVCII

Output Levels

Rated power [VA]

13,500

15,000

Max. power [VA]

13,500

15,000

Grid voltage [V]

230/400

Rated current [A]

3 x 19.5

3 x 21.7

Max. current [A]

3 x 19.5

3 x 21.7

Rated frequency [Hz]

50/60

cos phi

0.80 inductive to 0.80 capacitive

Number of feed-in phases

3

Distortion factor [%]

<3

AC overvoltage category

OVCIII

General electrical data

Max. effi

ciency [%]

96.2

European effi

ciency [%]

95.6

Internal consumption: standby [W]

< 10

Internal consumption: night [W]

1.9

Feed-in starts at [W]

180

Circuit design

Self-commutated, galvanically isolated, RF transformer

Transformer unit

Yes

Grid monitoring

Country-specifi c

CE conformity

Yes

Clock frequency [kHz]

17

Table 1:

Electrical data