8 confi guration and operation, 1 controls, 1 led indicators – KACO Powador 16.0 TR3 User Manual
Page 27
C o n f i g u r a t i o n a n d O p e r a t i o n
Page 28
Operating Instructions Powador 16.0 TR3, 18.0 TR3_EN
8 Confi guration and Operation
8.1 Controls
The inverter has a backlit LCD as well as three status LEDs. The inverter is operated using six buttons.
Fig 12:
Control panel
Key
1
“Operating” LED
5
4-way button
2
“Feed-in” LED
6
“OK” button
3
“Fault” LED
7
“ESC” button
4
LCD
8.1.1 LED
indicators
The three LEDs on the front of the inverter show the various operating states.
The LEDs can take on the following states:
LED illuminated
LED fl ashing
LED not illuminated
The LED indicators show the following operating states:
Operating state
LEDs
Display
Description
Start
The green “Operating” LED is on when AC
voltage is present, independent of the DC
voltage.
Feed-in start
Power fed into the grid
or measured values
The green “Operating” LED is illuminated.
The green “Feed-in” LED is illuminated
after the country-specifi c waiting period*.
The inverter is ready to feed in, i.e. is on
the grid.
You can hear the line relay switch on.
* The waiting period ensures that the generator voltage continuously remains above the power delivery limit
of 200 V. For the country-specifi c waiting times, see section 4.3 on page 15.