C o n f i g u r a t i o n a n d O p e r a t i o n

Page 34

Operating Instructions Powador 16.0 TR3, 18.0 TR3_EN

Country-

spec. setting

Menu

level

Display/

Setting

Action in this menu/meaning

All countries

0

1

2

3

1

Interface

 If the inverter is a terminal unit: Activate termination

(“Bus termination” menu item)

 Assign a unique RS485 bus address to the inverter

(“proLOG address” menu item). The address must
not be the same as that of another inverter or a
proLOG unit.

0

1

2

3

1

S0 pulse rate

 Set the pulse rate of the S0 connection.

DE

0

1

2

3

1

Activ. Relay 33

Releases the use of the fault signal relay for internal con-
sumption control relay 33.

1.

Enter the password.

2. Confi rm the entry with the OK button.

3. Activate or deactivate the home feed-in function.

NOTICE: Activating this option enables the menu item
Relay 33 set.

0

1

2

3

1

Relay 33 set.

 Defi ne the switch-on power in kW that needs to be

available on an uninterrupted basis for 30 minutes
before the home feed-in is activated.

 Defi ne the switch-on time (operating time of relay

33 after activation).

NOTICE: This menu item is only available if you have
selected the “On” option for the menu item “Activ. Relay
33” in the “Settings” menu.

All countries

0

1

2

3

1

Quick start

 Reduce the waiting times during the self test by

pressing the “Activate” button.

0

1

2

3

1

Logging interval

 Set the time between two log data recordings.

0

1

2

3

1

Log data backup

The inverter supports the backing up of all recorded
yield data to a connected USB storage device.

 Activate or deactivate log data backup.

0

1

2

3

1

Display

 Confi gure the contrast setting for the display.

 Set the length of time without user input after

which the backlighting of the LCD switches off .

 Alternatively: activate or deactivate backlighting

permanently by selecting “On” or “Off ”.

0

1

2

3

1

Date & time

 Set the time and date.
NOTICE: For self-diagnostic purposes, the inverter car-
ries out a daily restart at midnight. To avoid having a
restart occur during feed-in operation and to always
obtain reliable log data, ensure that the time is correctly
set.

0

1

2

3

1

Ethernet

 Assign a unique IP address.

 Assign a subnet mask.

 Assign a gateway.