beautypg.com

KACO XP10U-H4 User Manual

Page 48

background image

M a i n t e n a n c e / T r o u b l e s h o o t i n g

Page 48

Installation Instructions blueplanet XP10U H4 / H6 and XP10U H4 / H6 PSD

Status

Display

Explanation

Action

FS

81,
82,
83

Protect. shutdown
line volt.
L1 L2, L3

Overvoltage has been detected on
a conductor. An internal protective
mechanism has disconnected the
device to protect it against damage.

 In case of repeated

occurrence:
Notify your
authorised
electrician.

E

FS

84

Protect. shutdown
undervolt. DC link

A voltage deviation has been found
in the DC link. An internal protective
mechanism has disconnected the
device to protect it against damage.

 In case of repeated

occurrence:
Notify your
authorised
electrician.

E

FS

85

Protect. shutdown
overvolt. DC link

E

FS

86

Protect. shutdown
DC link asymmetry

Overvoltage has been found in
the DC link. An internal protective
mechanism has disconnected the
device to protect it against damage.

 In case of repeated

occurrence:
Notify your
authorised
electrician.

E

FS

87,
88,
89

Protection
shutdown
overcurrent L1, L2,
L3

A current that has been found
on a conductor is too high. An
internal protective mechanism has
disconnected the device to protect it
against damage.

 In case of repeated

occurrence:
Notify your
authorised
electrician.

E

FS

93,
94

Buff er 1, buff er 2
self test error

The control board is defective.

 Notify authorised

electrician / KACO
Service

E/K

FS

95,
96

Relay 1, relay 2 self
test error

The power section is defective.

 Notify KACO

Service

K

FS

97

Protect. shutdown
overcurrent HW

Too much power has been fed into
the grid. Complete disconnection of
the device.

 Notify authorised

electrician / KACO
Service

E/K

FS

98

Protect. shutdown
HW gate driver

An internal protective mechanism
has disconnected the device to
protect it against damage.

Complete disconnection of the
device.

 Notify authorised

electrician / KACO
Service

E/K

FS

99

Protect. shutdown:
HW buff er free

An internal protective mechanism
has disconnected the device to
protect it against damage.
Complete disconnection of the
device.

 Notify authorised

electrician / KACO
Service

E/K

FS

100

Protect. shutdown
HW overtemp.

The device has been switched off
because the temperatures in the
housing were too high.

 Check to make sure

that the fans are
working.

 Replace fan if

necessary.

B

E

Table 6: