T e c h n i c a l D a t a X P 1 0 U H 4 / H 6 ( w i t h o p t i o n a l P S D )

Page 12

Installation Instructions blueplanet XP10U H4 / H6 and XP10U H4 / H6 PSD

AC over current protection devices (OCPD)

Current limiting inverter, OCPD provided by system integrator

AC LOTO Provision

LOTO in OPEN

AC input terminals / conductor size

L1-L2-L3 / N (with optional PSD)

4 - 8 / 12 Awg

DC Disconnection means

Rotary switch accesible from inside of enclosure with no

tools required

DC Disconnection ratings

20 A, 4 pole, Load Break, Pos and Neg

DC over current protection devices (OCPD)

Current limiting inverter, OCPD provided by system integrator

DC LOTO Provision

LOTO in OPEN

DC input terminals / conductor size, per channel

(with optional PSD)

2 Pos and 2 Neg / 6 -14 AWG

Mechanical and environmental specifi cations

Mechanical integration

Ground mount, Roof Mount

Enclosure construction

Cast Al for XP10U, Power coated steel for PSD.

Unit Weight (lb/kg)

Inv and Inv with PSD

88 /40

100 / 45

Unit dimensions HxWxD (In/mm)

(37 x 16.5 x 7.9 / 940 x 420 x 200)

(27.2 x 16.5 x 7.9 / 690 x 420 x 200)

Environmental

Operating temp range (°F / °C)

(-13 to 140 / -25 to 60)

Storage temp range (°F / °C)

(-22 to 158 / -30 to 70)

Noise emissions

< 55 db

Humidity %

0 to 95 non condensing

Enclosure rating Inverter / PV system disconnect

NEMA 4

Cooling

Forced convection with variable speed fan

Altitude (ft / m)

6500 / 2000

Communications and user interface

User interface

Graphical user interface with 3 LED status indicators

Connectivity

(Ethernet / USB / RS485 / S0 output)

Safety features and regulatory compliance

UL / IEEE / CSA / FCC

UL 1741x 2nd Ed 2010 / CSA C22.2No 107.1 / IEEE 1547 /

FCC Class B /

Fault signal relay

Potential free normally open contact

DC polarity safegaud

Short circuit diode

GFDI compliant with NEC 690.35 for use with

ungrounded PV system arrays.

UL1741 listed for residual ground fault current isolation