10 service – KACO blueplanet 3.0 - 4.6 TL1 User Manual
Page 52
EN
EN
Service
Page 52
Operating Instructions for KACO blueplanet 3.0-4.6 TL1
Status
Display
Explanation
Action
FS
101
to
106
Temperature plau-
sibility error, effi
-
ciency, DC link, AFI
module, relay, DC/
DC converter
The unit has shut down because
of implausible internal measured
values.
Notify KACO Service
K
FS
125
AC relay error relay
control
Release signal for the relay control
is fed back. The shutdown is carried
out if the level is incorrect.
Notify KACO Service
K
FS
131
132
Arc detected on
DC1 / DC2
Arc or other external infl uences
generate an interference spectrum.
Possible cause: Incorrect connectors,
faulty cables or modules.
Check the system
Error reset possible
via menu option.
E
B
FS
134
AFCI power supply
critical
Supply voltage of the AFCI is outside
the tolerance.
Notify KACO Service
K
Table 4:
Operating status and fault messages on the display
10
Service
If you need help solving a technical problem with one of our KACO products, please contact our service hotline.
Please have the following information ready so that we can help you quickly and effi
ciently:
•
Device name / serial number
•
Date of installation / Start-up report
•
Fault message shown on the display / Description of the fault / Did you notice anything unusual? / What has
already been done to analyse the fault?
•
Module type and string circuit
•
Consignment identifi cation / Delivery address / Contact person (with telephone number)
•
Information about the accessibility of the installation site.
Any additional costs arising from unfavourable structural or mounting conditions shall be billed to the customer.
You can fi nd the following items and other information at our web site http://www.kaco-newenergy.de/:
•
our current warranty conditions,
•
a complaint form,
•
a form for registering your device with us. Please register your unit without delay. In this manner, you can assist us
in providing you with the quickest service possible.
Note: The maximum length of the warranty is based on the currently applicable national warranty conditions.
Hotlines
Technical troubleshooting
Technical consultation
Inverter
+49 (0) 7132/3818-660
+49 (0) 7132/3818-660
Data logging and accessories
+49 (0) 7132/3818-690
+49 (0) 7132/3818-690
Customer help desk
Monday to Friday from 8:00 - 12.00 a.m. and 1:00 - 5:00 p.m. (CET)