Technical Data

Page 10

Operating Instructions for KACO blueplanet 3.0-4.6 TL1

4 Technical

Data

4.1

Electrical

Data

Product: KACO blueplanet

3.0 TL1 M1

3.0 TL1

3.5 TL1

3.7 TL1

Input levels

DC MPP range from [V] to [V]

280 ... 510

140 ... 510

165 ... 510

170 ... 510

Operating range from [V] to [V]

125 ... 550

Starting voltage [V]*

150

No-load voltage (U

OC max

) [V]

600 (start to 550)

Max. input current [A]

11

2 x 11

2 x 11

Max. power per tracker [W]

3100

3100

3600

3800

Number of strings

1

2

2

Number of MPP controls

1

2

2

Max. short-circuit current [A]

25

Polarity safeguard

Short-circuit diode

Overvoltage category

III

Output levels

Rated power [VA]

3000

3000

3450

3680

Grid voltage [V]

230 (1/N/PE)

Rated current [A]

13.0

13.0

15.0

16.0

Max. rated current [A]

14.5

14.5

16.6

17.7

Rated frequency [Hz]

50

cos phi

0.30 inductive ... 0.30 capacitive

Number of feed-in phases

1

THD [%]

1.42

1.42

0.79

0.79

Overvoltage category

III

General electrical data

Max. effi

ciency [%]

97.2

97.2

97.2

97.2

European effi

ciency [%]

96.5

96.5

96.5

96.5

Make current [A] [RMS (20 ms)]

1.82

Internal consumption: night [W]

3

Feed-in starts at [W]

20

Circuit design

Transformerless

Grid monitoring

Country-specifi c

Ground fault monitoring

Yes