4 technical data, 1 electrical data – KACO blueplanet 3.0 - 4.6 TL1 User Manual
Page 10
EN
EN
Technical Data
Page 10
Operating Instructions for KACO blueplanet 3.0-4.6 TL1
4 Technical
Data
4.1
Electrical
Data
Product: KACO blueplanet
3.0 TL1 M1
3.0 TL1
3.5 TL1
3.7 TL1
Input levels
DC MPP range from [V] to [V]
280 ... 510
140 ... 510
165 ... 510
170 ... 510
Operating range from [V] to [V]
125 ... 550
Starting voltage [V]*
150
No-load voltage (U
OC max
) [V]
600 (start to 550)
Max. input current [A]
11
2 x 11
2 x 11
Max. power per tracker [W]
3100
3100
3600
3800
Number of strings
1
2
2
Number of MPP controls
1
2
2
Max. short-circuit current [A]
25
Polarity safeguard
Short-circuit diode
Overvoltage category
III
Output levels
Rated power [VA]
3000
3000
3450
3680
Grid voltage [V]
230 (1/N/PE)
Rated current [A]
13.0
13.0
15.0
16.0
Max. rated current [A]
14.5
14.5
16.6
17.7
Rated frequency [Hz]
50
cos phi
0.30 inductive ... 0.30 capacitive
Number of feed-in phases
1
THD [%]
1.42
1.42
0.79
0.79
Overvoltage category
III
General electrical data
Max. effi
ciency [%]
97.2
97.2
97.2
97.2
European effi
ciency [%]
96.5
96.5
96.5
96.5
Make current [A] [RMS (20 ms)]
1.82
Internal consumption: night [W]
3
Feed-in starts at [W]
20
Circuit design
Transformerless
Grid monitoring
Country-specifi c
Ground fault monitoring
Yes
* The DC starting voltage can be in the menu if needed.