7 installation, 1 opening the connection area, 2 confi gure connections – KACO blueplanet 3.0 - 4.6 TL1 User Manual
Page 18
EN
EN
Installation
Page 18
Operating Instructions for KACO blueplanet 3.0-4.6 TL1
Authorised electrician
7 Installation
DANGER
Lethal voltages are still present in the terminals and cables of the inverter even after the
inverter has been switched off and disconnected.
Severe injuries or death result if the cables and terminals in the inverter are touched.
Only appropriately qualifi ed and authorised electricians may open and install the inverter.
The inverter must be mounted in a fi xed position before being connected electrically.
›
Observe all safety regulations and current technical connection specifi cations of the responsible
power supply company.
›
Disconnect the AC and DC sides.
›
Secure both sides against being inadvertently switched back on.
›
Ensure that the AC and DC sides are completely isolated and voltage free.
›
Connect the inverter only after the aforementioned steps have been taken.
7.1
Opening the connection area
1
2
3
Figure 9: Disassemble the cover
Figure 10: Remove the cover
Figure 11: Remove the slider
Key
1
Screws for mounting (x2)
2
Cover for the connection area
3
Slider
7.2 Confi gure connections
7.2.1 Confi guring the AC connector
NOTE
If your grid operator or power supply company requests 3-phase power monitoring, a 3-phase
(fi ve-pin) power supply is required. The 3-phase monitoring must be also activated in the "Parame-
ters" menu (see Chapter 8.3 on page 31). Before installation, ask your grid operator or power
supply company about the necessary grid connection.
NOTE
The permissible bending radius of at least 4 x the cable diameter should be observed during installa-
tion. Excessive bending force may negatively impact the protection rating.
All mechanical loads must be absorbed in front of the plug connection.