24 software reset (fn030), 1) preparation, 2) operating procedure – Yaskawa Sigma-5 User Manual: Operation of Digital Operator User Manual
Page 88

3 Utility Function Mode
3.2.24 Software Reset (Fn030)
3-54
3.2.24 Software Reset (Fn030)
This function enables resetting the SERVOPACK internally from software. This
function is used when resetting alarms and changing the settings of parameters that
normally require restarting the SERVOPACK. This function can be used to change
those parameters without restarting the SERVOPACK.
(1) Preparation
The following condition must be met to perform a software reset.
• The servomotor power must be OFF.
(2) Operating Procedure
Use the following procedure.
• Start software reset operation after the servomotor power
is OFF.
• This function resets the SERVOPACK independently of
host controller. The SERVOPACK carries out the same
processing as when the power supply is turned ON and
outputs the ALM signal. The status of other output signals
may be forcibly changed.
Step
Display after Operation
Keys
Operation
1
Press the
Key to view the main
menu for the utility function mode.
Use the
or
Key to move
through the list and select Fn030.
2
Press the
Key. The display changes
to the Fn030 execution display.
3
Press the
or
Key to select
“RESET5”.
B B
− F U N C T I O N −
F n 0 2 0 : S
− O r i g S e t
F n 0 3 0 : S o f t R e s e t
F n 0 8 0 : P o l e D e t e c t
F n 2 0 0 : T u n e L v l S e t
B B
S o f t w a r e R e s e t
R E S E T 1
B B
S o f t w a r e R e s e t
R E S E T 5