3 Utility Function Mode

3.2.31 Vibration Suppression Function (Fn205)

3-88

(1) Preparation

The following conditions must be met to perform the vibration suppression function.

The message “NO-OP” indicating that the settings are not appropriate will be dis-
played, if all of the following conditions are not met.

• The control must be set to position control.
• The tuning-less function must be disabled (Pn170.0 = 0).
• The test without a motor function must be disabled (Pn00C.0 = 0).
• The write prohibited setting (Fn010) must not be set to write-protect parameters.

(2) Operating Procedure

Step

Display after Operation

Keys

Operation

1

Input a operation reference and take the following steps while repeating positioning.

2

Press the

Key to view the main menu

for the utility function mode.
Use the

or

Key to move

through the list, select Fn205.

3

Press the

Key. The display shown on

the left will appear.

Measure f: Measurement frequency

Setting f: Setting frequency [Factory-set to the

set value for Pn145]

If the setting frequency and actual operating

frequency are different, “Setting” will flash.

Note:

Frequency detection will not be performed if

there is no vibration or the vibration fre-

quency is outside the range of detectable fre-

quencies. The following screen will be

displayed if vibration is not detected. If the

vibration frequencies are not detected, prepare

a means of detecting and measuring the vibra-

tion. When the vibration frequencies are mea-

sured, go to step 5 and manually set the

measured vibration frequency to “Setting f.”