1) preparation, 2) operating procedure – Yaskawa Sigma-5 User Manual: Operation of Digital Operator User Manual
Page 41

3.2 Operations
3-7
9
head1
3
Utility Function Mode
(1) Preparation
There are no tasks that must be performed before displaying the alarm history.
(2) Operating Procedure
Use the following procedure.
Note: 1. If the same alarm occurs after more than one hour, the alarm will be saved. If it
occurs in less than one hour, it will not be saved.
2. The display “.---” means no alarm occurs.
3. Delete the alarm history using the parameter Fn006. The alarm history is not cleared
on alarm reset or when the SERVOPACK main circuit power is turned OFF.
Step
Display after Operation
Keys
Operation
1
Press the
Key to view the main
menu for the utility function mode.
Use the
or
Key to move
through the list and select Fn000.
2
Press the
Key. The display changes
to the Fn000 execution display.
3
Press the
or
Key to scroll
through the alarm history. The alarm his-
tory can be viewed.
4
Press the
Key.
The display returns to the main menu of the
utility function mode.