3 Utility Function Mode

3.2.33 Online Vibration Monitor (Fn207)

3-96

3

Press the

Key for at least one sec-

ond to start vibration detection. The

Key must be pressed until “Measure”

flashes on the display. After this message
appears, the

Key does not have to

be pressed and the detection continues

automatically.

4

When the vibration detection has com-

pleted, “Measure” stops flashing and the

detection processing ends automatically.

When the detection processing has com-

pleted normally, the vibrations with three

largest peak values in vibration frequency

are displayed for F1, F2, and F3.

Notes:

• Press the

Key to quit the online

vibration monitor function. The display

returns to the main menu of the utility

function mode.

• A detected frequency can be displayed.

For a vibration with undetectable peak

frequency, “----” is displayed. If no fre-

quency was detected, “----” is displayed

for F1, F2, and F3.

• If the frequency could not be success-

fully detected, “NO MONITOR” is dis-

played.

5

After the detection has normally com-
pleted, press the

Key. The optimum

frequency (time constant) of notch filter or

torque reference filter for F1 is set auto-

matically. At the same time, the parameter

Pn409 is updated for a notch filter, or the

parameter Pn401 is updated for a torque

reference filter.

After the setting is successfully completed,

“DONE” flashes.

6

Press the

Key.

The display returns to the main menu of the

utility function mode.

(cont’d)

Step

Display after Operation

Keys

Operation