3.2 Operations
3-19
9
head1
3
Utility Function Mode
3.2.6 Clearing Alarm History (Fn006)
The clear alarm history function deletes all of the alarm history recorded in the SER-
VOPACK.
Note: The alarm history is not deleted when the alarm reset is executed or the main circuit
power supply of the SERVOPACK is turned OFF.
(1) Preparation
The follow conditions must be met to clear the alarm history.
• The write prohibited setting (Fn010) must not be set to write-protect parameters.
(2) Operating Procedure
Use the following procedure.
Step
Display after Operation
Keys
Operation
1
Press the
Key to view the main
menu for the utility function mode.
Use the
or
Key to move
through the list and select Fn006.
2
Press the
Key. The display
changes to the Fn006 execution dis-
play.
3
Press the
Key to clear the alarm
history.
While clearing the data, “DONE” is
displayed in the status display. After
the data has been successfully cleared,
“BB” is displayed.
Note: Press the
Key not to
clear the alarm history. The dis-
play returns to the main menu of
the utility function mode.