background image

4 Parameter Copy Mode

4.2.2 Write-in Parameters (OP

→ SERVO)

4-8

(2) Notes on Write-in Parameters Function

• Do not disconnect the digital operator from the SERVOPACK while the parame-

ters are being written in. Otherwise, the writing process is cancelled, and a part of
parameters are not written in. In such case, re-execute the writing operation. Turn-
ing the power OFF then ON before re-executing the writing operation may cause a
Parameter Checksum Error (A.020) or Parameter Setting Error (A.040). To clear
an alarm, execute Fn005 “Initialize Parameter Settings.”

• If an empty block (“

∗∗∗∗

”) is selected and the Write-in Parameter function is exe-

cuted, the message “No Data” is displayed and the writing will a not be executed.

• Writing a parameter block to a SERVOPACK with a different voltage and capacity

displays the message “Unmatched Parameters” and the parameters cannot be writ-
ten.

• If the servo is turned ON, “Not Available” will appear for the Write-prohibit set-

ting, and the parameters cannot be written.

• While writing in parameters, the steps are displayed in sequence as they are being

processed. The SERVOPACK can write in parameters in 10 seconds.

• After the parameter block has been written into the SERVOPACK, turn the power

OFF then ON again. The servo ON input signal is invalid until the setting valida-
tion is executed.

While reading the parameters from
the digital operator

While writing the parameters into
the SERVOPACK

Note: While this display is on screen, the operation is not cancelled

by pressing the Key.

Operation completed