3 Utility Function Mode

3.2.15 Write Prohibited Setting (Fn010)

3-36

3.2.15 Write Prohibited Setting (Fn010)

This function prevents changing parameters by mistake and sets restrictions on the
execution of the utility function.

Parameter changes and execution of the utility function become restricted in the fol-
lowing manner when the write prohibited setting is set.

• Parameters: Cannot be changed. If you attempt to change it, “NO-OP” will flash

on the display and the screen will return to the main menu.

• Utility Function: Some functions cannot be executed. (Refer to the following

table.) If you attempt to execute these utility functions, “NO-
OP” will flash on the display and the screen will return to the
main menu.

Parameter

No.

Function

Write Prohibited

Setting

Fn000

Alarm history display

Executable

Fn002

JOG operation

Cannot be executed

Fn003

Origin search

Cannot be executed

Fn004

Program JOG operation

Cannot be executed

Fn005

Initializing parameter settings

Cannot be executed

Fn006

Clearing alarm history

Cannot be executed

Fn008

Absolute encoder multiturn reset and encoder

alarm reset

Cannot be executed

Fn009

Automatic tuning of analog (speed, torque) ref-

erence offset

Cannot be executed

Fn00A

Manual servo turning of speed reference offset

Cannot be executed

Fn00B

Manual servo turning of torque reference offset

Cannot be executed

Fn00C

Offset adjustment of analog monitor output

Cannot be executed

Fn00D

Gain adjustment of analog monitor output

Cannot be executed

Fn00E

Automatic offset-signal adjustment of the motor

current detection signal

Cannot be executed

Fn00F

Manual offset-signal adjustment of the motor

current detection signal

Cannot be executed

Fn010

Write prohibited setting

Fn011

Servomotor model display

Executable

Fn012

Software version display

Executable

Fn013

Multiturn limit value setting change when a

multiturn limit disagreement alarm occurs

Cannot be executed

Fn014

Resetting configuration error in option modules

Cannot be executed