DC Input

* The maximum open-circuit voltage, which can occur at a cell temperature of − 10°C, must not exceed the maximum input voltage.

AC output

Maximum DC power at cos φ = 1

7 500 W

Maximum input voltage*

800 V

MPP voltage range

335 V … 560 V

Rated input voltage

340 V

Minimum input voltage

290 V

Start input voltage

400 V

Maximum input current

23 A

Maximum input current per string

23 A

Number of independent MPP inputs

1

Strings per MPP input

4

Rated power at 230 V, 50 Hz

6 650 W

Maximum apparent AC power

7 000 VA

Rated grid voltage

230 V

Nominal AC voltage

220 V / 230 V / 240 V

AC voltage range

180 V … 265 V

AC nominal current at 220 V

30.2 A

AC nominal current at 230 V

28.9 A

AC nominal current at 240 V

27.7 A

Maximum output current

31 A

Total harmonic factor of output current at
AC THF < 2%,
AC power > 0.5 rated power

≤ 3%

Rated power frequency

50 Hz

AC power frequency

50 Hz / 60 Hz

Operating range at AC power frequency 50 Hz

44 Hz … 55 Hz

Operating range at AC power frequency 60 Hz

54 Hz … 65 Hz

Displacement power factor, adjustable

0.8

overexcited

… 0.8

underexcited

Feed-in phases

1

Connection phases

1

Overvoltage category as per IEC 60644-1

III