3 setting the display language, Setting the display language – SMA SMC 7000HV Installation User Manual
Page 29

SMA Solar Technology AG
Electrical Connection
Installation Manual
SMC70HV11-IA-IEN112970
29
5.3 Setting the Display Language
You can set the language of the display using the switches on the underside of the display board
inside the inverter.
When selecting the display language, different switching settings apply to inverters that are set to the
Italian national standard DK 5940. You can see the standard to which the inverter was set upon
delivery from the type label and the supplementary document provided with the factory settings.
For more information on setting the grid and national parameters, see section 5.7 "Setting the Grid
and Country Parameters" (page 47).
Procedure
1. Open the inverter as described in section 7.2 "Opening the Inverter" (page 56).
2. Set the switches to the required language, as
shown below.
The following switch settings, except for DK 5940,
apply to all national standards:
The following switch settings apply to inverters that
are set to the Italian national standard DK 5940:
3. Close the inverter as described in section 7.3 "Closing the Inverter" (page 59).
☑ The display language is set.
Language
Switch S2
Switch S1
German
B
B
English
B
A
French
A
B
Spanish
A
A
Language
Switch S2
Switch S1
Italian
B
A
English
A
A
German
B
B
French
A
B