beautypg.com

SMA SMC 7000HV Installation User Manual

Page 36

background image

Electrical Connection

SMA Solar Technology AG

36

SMC70HV11-IA-IEN112970

Installation Manual

– Insert the sealing plug into the DC connector.

– Tighten the DC plug connector (torque: 2 Nm).

– Insert the DC connectors with sealing plugs into

the corresponding DC inputs on the inverter.

☑ The DC connectors click audibly into position.

7. Ensure that all DC plug connectors are securely

in place.

8. Check the Electronic Solar Switch for wear, as

described in section 8.3 "Checking the Electronic
Solar Switch (ESS) for Wear" (page 65)
and attach
it firmly.

NOTICE!
Manipulating the connector in the handle can damage the
Electronic Solar Switch!
The connector inside the handle must remain movable in order to ensure proper contact.
Tightening the screw voids all warranty claims and creates a fire risk.

• Do not tighten the connector screw in the Electronic Solar Switch handle.

+

+