beautypg.com

9 troubleshooting, 1 blink codes, Troubleshooting – SMA SMC 7000HV Installation User Manual

Page 66: Blink codes

background image

Troubleshooting

SMA Solar Technology AG

66

SMC70HV11-IA-IEN112970

Installation Manual

9 Troubleshooting

If the inverter displays other blink codes or fault messages than those described below, contact the
SMA Serviceline.
You will also find a description of display messages during operation, status messages and measuring
channels in the user manual provided.
Do not perform any repairs that are not described here and take advantage of the 24-hour
replacement service (inverter ready for shipping and handed over to a freight-forwarding company
within 24 hours) and the SMA Solar Technology AG repair service instead.

9.1 Blink Codes

Green

Red

Yellow

Status

Flashes

Flashes

Flashes

OK (startup phase)

is glowing continuously is not glowing

is not glowing

OK (feed-in operation)

is glowing continuously is not glowing

Ground fault or varistor
defective

is glowing continuously OK (startup phase)

is flashing quickly
(3 x per second)

is not glowing

is not glowing

OK (stop)

is glowing continuously is not glowing

Ground fault or varistor
defective

is flashing slowly
(1 x per second)

is not glowing

is not glowing

OK (waiting, grid
monitoring)

goes out briefly
(approx. 1 x per
second)

is glowing continuously is not glowing

Ground fault or varistor
defective

is not glowing

is not glowing

OK (derating)

is not glowing

is not glowing

is not glowing

OK (nighttime
deactivation or
Electronic Solar Switch
not connected)

is glowing/flashing

Fault

is glowing continuously is not glowing

Ground fault or varistor
defective

is glowing/flashing

Ground fault or varistor
defective and
disturbance