9 troubleshooting, 1 blink codes, Troubleshooting – SMA SMC 7000HV Installation User Manual
Page 66: Blink codes

Troubleshooting
SMA Solar Technology AG
66
SMC70HV11-IA-IEN112970
Installation Manual
9 Troubleshooting
If the inverter displays other blink codes or fault messages than those described below, contact the
SMA Serviceline.
You will also find a description of display messages during operation, status messages and measuring
channels in the user manual provided.
Do not perform any repairs that are not described here and take advantage of the 24-hour
replacement service (inverter ready for shipping and handed over to a freight-forwarding company
within 24 hours) and the SMA Solar Technology AG repair service instead.
9.1 Blink Codes
Green
Red
Yellow
Status
Flashes
Flashes
Flashes
OK (startup phase)
is glowing continuously is not glowing
is not glowing
OK (feed-in operation)
is glowing continuously is not glowing
Ground fault or varistor
defective
is glowing continuously OK (startup phase)
is flashing quickly
(3 x per second)
is not glowing
is not glowing
OK (stop)
is glowing continuously is not glowing
Ground fault or varistor
defective
is flashing slowly
(1 x per second)
is not glowing
is not glowing
OK (waiting, grid
monitoring)
goes out briefly
(approx. 1 x per
second)
is glowing continuously is not glowing
Ground fault or varistor
defective
is not glowing
is not glowing
OK (derating)
is not glowing
is not glowing
is not glowing
OK (nighttime
deactivation or
Electronic Solar Switch
not connected)
is glowing/flashing
Fault
is glowing continuously is not glowing
Ground fault or varistor
defective
is glowing/flashing
Ground fault or varistor
defective and
disturbance