7.2 Plant Extension

7.2.1 Adding Inverters to the Plant

Procedure

See

1

For a new inverter, set the NetID of the plant:

• For inverters with integrated Bluetooth, set the NetID in the

inverter.

• For inverters with retrofitted SMA Bluetooth Piggy-Back, set the

NetID at the fitted SMA Bluetooth Piggy-Back.

Inverter Installation
Manual or SMA

Bluetooth Piggy-Back

2

Commission the new inverters.

Inverter Installation
Manual

3

For new inverters, use Sunny Explorer to set the plant passwords

*

of

the plant.

* Plant passwords of the user groups "User" and "Installer"

Sunny Explorer help

4

Repeat the plant search in the Sunny Beam.

Section 6.10

5

In the Sunny Beam, set the revenue per kWh for new inverters.

Section 7.2.3