Device Replacement/Plant Extension (Installer)

SMA Solar Technology AG

64

BeamBT11-BA-BEN112713

User Manual

7.1.3 Adjusting the Energy Meter of an Inverter

The energy meter (total energy value) of an inverter must be adjusted in the inverter in the event of an
inverter replacement by the installer. Otherwise, an incorrect total energy value (E-Total) will be
displayed (e.g. for the Sunny WebBox, on large displays, in the Sunny Portal).
If the energy meter in the inverter is not adjusted, you can adjust the value shown in the Sunny Beam.
This adjustment only affects the data of the Sunny Beam, not the inverter. Set the total energy value
(E-Total) of the previous inverter in the Sunny Beam for the new inverters. You can determine the total
energy value of the previous inverter from the CSV files (see section 5.7).

1. Select Settings > PV plant > Offset energy meter.
2. Select the new inverter.
3. Select Display.
4. Set the total energy value of the previous inverter.