beautypg.com

7 device replacement/plant extension (installer), 1 device replacement, 1 replacing inverters in the plant – SMA BEAM-BT-11 User Manual

Page 62: Device replacement/plant extension (installer), Device replacement, Replacing inverters in the plant

background image

Device Replacement/Plant Extension (Installer)

SMA Solar Technology AG

62

BeamBT11-BA-BEN112713

User Manual

7 Device Replacement/Plant Extension (Installer)

7.1 Device Replacement

7.1.1 Replacing Inverters in the Plant

Procedure

See

1

Note the total energy value of the previous inverter:

• For inverters with a display, read the total energy value

(E-Total) of the inverter on its display.

• For inverters without a display, detect plants with

Sunny Explorer and read the total energy value of the inverter
in the Sunny Explorer.

Inverter Installation
Manual or
Sunny Explorer help

2

Decommission the previous inverters.

Inverter Installation
Manual

3

For a new inverter, set the NetID of the plant:

• For inverters with integrated Bluetooth, set the NetID in the

inverter.

• For inverters with retrofitted SMA Bluetooth Piggy-Back, set the

NetID at the fitted SMA Bluetooth Piggy-Back.

Inverter Installation
Manual or SMA

Bluetooth Piggy-Back

4

Commission the new inverters.

Inverter Installation
Manual

5

For new inverters, use Sunny Explorer to set the plant passwords

*

of

the plant.

Sunny Explorer help