7 device replacement/plant extension (installer), 1 device replacement, 1 replacing inverters in the plant – SMA BEAM-BT-11 User Manual
Page 62: Device replacement/plant extension (installer), Device replacement, Replacing inverters in the plant
Device Replacement/Plant Extension (Installer)
SMA Solar Technology AG
62
BeamBT11-BA-BEN112713
User Manual
7 Device Replacement/Plant Extension (Installer)
7.1 Device Replacement
7.1.1 Replacing Inverters in the Plant
Procedure
See
1
Note the total energy value of the previous inverter:
• For inverters with a display, read the total energy value
(E-Total) of the inverter on its display.
• For inverters without a display, detect plants with
Sunny Explorer and read the total energy value of the inverter
in the Sunny Explorer.
Inverter Installation
Manual or
Sunny Explorer help
2
Decommission the previous inverters.
Inverter Installation
Manual
3
For a new inverter, set the NetID of the plant:
• For inverters with integrated Bluetooth, set the NetID in the
inverter.
• For inverters with retrofitted SMA Bluetooth Piggy-Back, set the
NetID at the fitted SMA Bluetooth Piggy-Back.
Inverter Installation
Manual or SMA
Bluetooth Piggy-Back
4
Commission the new inverters.
Inverter Installation
Manual
5
For new inverters, use Sunny Explorer to set the plant passwords
*
of
the plant.
Sunny Explorer help