3.8 UNIVER

SAL PECKING (Cy

c

le 205,

DIN/ISO: G205, A

d

v

a

nced Pr

ogr

a

mming

F

e

at

ur

es Sof

tw

a

re

Option)

Cycle parameters

U

Setup clearance Q200 (incremental): Distance

between tool tip and workpiece surface. Input range
0 to 99999.9999

U

Depth Q201 (incremental): Distance between

workpiece surface and bottom of hole (tip of drill
taper). Input range -99999.9999 to 99999.9999

U

Feed rate for plunging Q206: Traversing speed of

the tool during drilling in mm/min. Input range: 0 to
99999.999; alternatively FAUTO, FU.

U

Plunging depth Q202 (incremental): Infeed per cut.

Input range 0 to 99999.9999. The depth does not
have to be a multiple of the plunging depth. The TNC
will go to depth in one movement if:

„

the plunging depth is equal to the depth

„

the plunging depth is greater than the depth

U

Workpiece surface coordinate Q203 (absolute):

Coordinate of the workpiece surface. Input range:
-99999.9999 to 99999.9999

U

2nd setup clearance Q204 (incremental): Coordinate

in the spindle axis at which no collision between tool
and workpiece (fixtures) can occur. Input range 0 to
99999.9999

U

Decrement Q212 (incremental): Value by which the

TNC decreases the plunging depth Q202. Input range
0 to 99999.9999

U

Minimum plunging depth Q205 (incremental): If you

have entered a decrement, the TNC limits the
plunging depth to the value entered with Q205. Input
range 0 to 99999.9999

U

Upper advanced stop distance Q258 (incremental):

Setup clearance for rapid traverse positioning when
the TNC moves the tool again to the current plunging
depth after retraction from the hole; value for the first
plunging depth. Input range 0 to 99999.9999

U

Lower advanced stop distance Q259 (incremental):

Setup clearance for rapid traverse positioning when
the TNC moves the tool again to the current plunging
depth after retraction from the hole; value for the last
plunging depth. Input range 0 to 99999.9999

X

Z

Q200

Q201

Q206

Q202

Q203

Q204

Q211

Q257