1 fundamentals, Overview, 1 f undamentals 14.1 fundamentals – HEIDENHAIN TNC 620 (340 56x-02) Cycle programming User Manual
Page 288

288
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
14.1 F
undamentals
14.1 Fundamentals
Overview
The TNC provides five cycles that enable you to measure and
compensate workpiece misalignment. In addition, you can reset a
basic rotation with Cycle 404:
Danger of collision!
When running touch probe cycles, no cycles must be
active for coordinate transformation (Cycle 7 DATUM,
Cycle 8 MIRROR IMAGE, Cycle 10 ROTATION, Cycles 11
and 26 SCALING and Cycle 19 WORKING PLANE or 3D-
ROT).
The TNC must be specially prepared by the machine tool
builder for the use of a 3-D touch probe.
The touch probe cycles are available only with the Touch
probe function software option (option number #17).
Cycle
Soft key
Page
400 BASIC ROTATION Automatic
measurement using two points.
Compensation via basic rotation.
401 ROT OF 2 HOLES Automatic
measurement using two holes.
Compensation via basic rotation.
402 ROT OF 2 STUDS Automatic
measurement using two studs.
Compensation via basic rotation.
403 ROT IN ROTARY AXIS Automatic
measurement using two points.
Compensation by turning the table.
405 ROT IN C AXIS Automatic
alignment of an angular offset between
a hole center and the positive Y axis.
Compensation via table rotation.
404 SET BASIC ROTATION Setting any
basic rotation.