6 meas. circle outside (cycle 422, din/iso: g422), Cycle run, Please note while programming – HEIDENHAIN TNC 620 (340 56x-02) Cycle programming User Manual
Page 380
380
Touch Probe Cycles: Automatic Workpiece Inspection
16.6 MEA
S
. CIR
C
LE OUTSIDE
(Cy
c
le 422, DIN/ISO: G422)
16.6 MEAS. CIRCLE OUTSIDE
(Cycle 422, DIN/ISO: G422)
Cycle run
Touch Probe Cycle 422 measures the center and diameter of a circular
stud. If you define the corresponding tolerance values in the cycle, the
TNC makes a nominal-to-actual value comparison and saves the
deviation value in system parameters.
1
The TNC positions the touch probe to the starting point
1
at rapid
traverse (value from FMAX column) following the positioning logic
(see “Executing touch probe cycles” on page 283). The TNC
calculates the touch points from the data in the cycle and the
safety clearance from the SET_UP column of the touch probe
table.
2
Then the touch probe moves to the entered measuring height and
probes the first touch point at the probing feed rate (column F). The
TNC derives the probing direction automatically from the
programmed starting angle.
3
Then the touch probe moves in a circular arc either at measuring
height or at clearance height to the next starting point
2
and probes
the second touch point.
4
The TNC positions the probe to starting point
3
and then to starting
point
4
to probe the third and fourth touch points.
5
Finally the TNC returns the touch probe to the clearance height and
saves the actual values and the deviations in the following Q
parameters:
Please note while programming:
X
Y
1
2
3
4
Parameter number
Meaning
Q151
Actual value of center in reference axis
Q152
Actual value of center in minor axis
Q153
Actual value of diameter
Q161
Deviation at center of reference axis
Q162
Deviation at center of minor axis
Q163
Deviation from diameter
Before a cycle definition you must have programmed a
tool call to define the touch probe axis.
The smaller the angle, the less accurately the TNC can
calculate the dimensions of the stud. Minimum input
value: 5°