HEIDENHAIN TNC 620 (340 56x-02) Cycle programming User Manual
Page 394

394
Touch Probe Cycles: Automatic Workpiece Inspection
16.9 MEA
S
URE INSIDE WIDTH (Cy
c
le 425, DIN/ISO: G425)
U
Measuring log Q281: Definition of whether the TNC
is to create a measuring log:
0: No measuring log
1: Generate measuring log: the TNC saves the log file
TCHPR425.TXT by default in the directory TNC:\.
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
U
PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
U
Tool number for monitoring Q330: Definition of
whether the TNC is to monitor the tool (see “Tool
monitoring” on page 368): Input range: 0 to 32767.9,
alternatively tool name with max. 16 characters
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
U
Setup clearance Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to SET_UP (touch probe table). Input range
0 to 99999.9999
U
Traversing to clearance height Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Example: NC blocks
5 TCH PROBE 425 MEASURE INSIDE WIDTH
Q328=+75
;STARTNG PNT 1ST AXIS
Q329=-12.5 ;STARTNG PNT 2ND AXIS
Q310=+0
;OFFS. 2ND MEASUREMENT
Q272=1
;MEASURING AXIS
Q261=-5
;MEASURING HEIGHT
Q260=+10
;CLEARANCE HEIGHT
Q311=25
;NOMINAL LENGTH
Q288=25.05 ;MAX. LIMIT
Q289=25
;MIN. LIMIT
Q281=1
;MEASURING LOG
Q309=0
;PGM STOP IF ERROR
Q330= ;TOOL
Q320=0
;SETUP CLEARANCE
Q301=0
;MOVE TO CLEARANCE