Module warnings and errors

Current, voltage, temperature, and non-volatile memory are monitored in MSE 1000 modules. Warnings and errors are
indicated in the Error screen and the status of the Power LED indicator on the affected module.

Warning or error

Cause

Corrective action

The current exceeds the warning

tolerance

MSE 1201: The current being drawn
from the power supply module is
> 2.0 A.

MSE 1202: The current being drawn
from the power supply module is
> 2.9 A.

The current exceeds the error

tolerance
Power LED:
Solid red.

MSE 1201: The current being drawn
from the power supply module is
> 2.1 A.

MSE 1202: The current being drawn
from the power supply module is
> 3.0 A.

Remove devices and/or modules

until the current is below the

tolerance.

or

Install additional power supply

modules into the module chain to

meet the current demand.

The 24V supply is below the

minimum warning tolerance

The 24 V supplied by the power
supply module to other modules is
< 21.5 V.

The 24V supply exceeds the

maximum warning tolerance

The 24 V supplied by the power
supply module to other modules is
> 26.5 V.

The 24V supply is below the

minimum error tolerance
Power LED:
Flashes red and green
at a rate of once per second.

The 24 V supplied by the power
supply module to other modules is
< 20 V.

The 24V supply exceeds the

maximum error tolerance
Power LED:
Flashes red and green
at a rate of once per second.

The 24 V supplied by the power
supply module to other modules is
> 28 V.

MSE 1201:

Contact HEIDENHAIN technical

support for assistance.

MSE 1202:

Verify that the 24 V output from

the external power supply is

providing the correct voltage.

If the external power supply is not

operating correctly, refer to the

documentation provided with it for

troubleshooting information.

If the external supply is providing

the correct voltage and the

warning or error persists:

Contact HEIDENHAIN technical

support for assistance.