Installation and commissioning examples
Example using manual IP address assignment
122
Operating Instructions
10.2.17 Setup the 1 V
PP
encoder
Open the device tab
Click the «Device» tab.
Select the reference
mark setting
Click the «Reference mark» drop-down arrow.
Select «Single».
Select the Signal
period setting
Click the «Signal period (um)» drop-down arrow.
Select «20».
Click the «OK» button.
Refer to "Device setup", page 89 for additional device settings.
10.2.18 Setup the EnDat channel
Select the EnDat
Channel
Click on «X11 (CH5)» under MSE 1314 in the Tree.
Click the «Channel» tab.
EnDat encoder types are automatically recognized when an EnDat encoder is
connected to a module channel.
Refer to "Channel setup", page 83 for additional channel settings options.
10.2.19 Setup the EnDat encoder
Open the Device tab
Click the «Device» tab.
Turn Error monitoring
off
Disabling error monitoring is useful for increasing communication speed with EnDat
v2.2 encoders. Refer to "Device setup", page 89 for additional device settings.
Click the «Error monitoring» drop-down arrow.
Select «Off».
Click the «OK» button.