beautypg.com

HEIDENHAIN MSE 1000 User Manual

Page 128

background image

Troubleshooting

Diagnostics

128

Operating Instructions

Module diagnostics

Power status

Displays "Ok" if the selected module is connected.

Voltage or temperature warnings and errors will be displayed in
the Tree and Error screen.

Bus status

Displays the network bus connection status of the selected
module.

Communication warnings will be displayed in the Error screen.

5V

Displays the voltage reading for the 5 V supply of the selected
module.

3.3V

Displays the voltage reading for the 3.3 V supply of the selected
module.

24V

Displays the voltage reading for the 24 V supply of the selected
module. Displayed for power supply modules only.

Current

Displays the electrical current being drawn from the selected
power supply module by non power supply modules and
connected devices.

CPU temperature

Displays the temperature of the microcontroller CPU inside
the selected module. CPU temperature is available only when
supervisor mode is enabled.