beautypg.com

HEIDENHAIN MSE 1000 User Manual

Page 108

background image

Operating information

Asynchronous message thread

108

Operating Instructions

Request

Parameters

A value of 151 must be put in the UDP packet.

A module number must be put in the UDP packet.

The required output number must be put in the UDP packet
(1-4).

The value is not used.

Toggles the desired output.

Toggle Output

No response is sent back.

A value of 152 must be put in the UDP packet.

A module number must be put in the UDP packet.

The required output number must be put in the UDP packet
(1-4).

The value must be 0 for off or 1 for on.

Sets the output to the desired value.

Set Output

No response is sent back.

A value of 153 must be put in the UDP packet.

The moduleNum is not used.

The channelNum is not used.

The value is used to determine which latch line to trigger (1-5).

A latch command is sent to the modules causing the data to be
updated in the Data screen and the Mse1000Data.xlsx Excel
spreadsheet.

Set Latch

No response is sent back.