Output of current value:
The current position value of each axis is output (without
comma, with leading zeros).
Example:
- 0 0 0 0 0 1 4 7 3
+ 0 0 0 0 0 0 0 0 0
String:
STX;
Algebraic sign; Numeric value with
9 characters; CR; LF; X axis
Algebraic sign; Numeric value with
9 characters; CR; LF; Y axis
Only with ND 760:
Algebraic sign; Numeric value with
9 characters; CR; LF; Z axis
Output of error text:
The displayed error text is output. (Prerequisite: an error
message is displayed.)
String:
STX;
13 characters; CR; LF;
Output of software number:
The current software number is output.
String:
STX;
10 characters; CR; LF;
Output of indicators:
The status display of each axis is output.
Example:
0 = Status symbol is dark
1 = Status symbol is on
2 = Status symbol blinks
0 1 0 0 1 0 1 0 0 0
0 0 0 0 1 0 0 0 0 0
a b c d e f g h i j
String:
STX;
10 characters; CR; LF;
X axis
10 characters; CR; LF;
Y axis
Only with ND 760:
10 characters; CR; LF;
Z axis
a = SET (set datum)
f = inch (inch display)
b = REF (reference point)
g = SCL (scaling factor)
c = distance-to-go display
h = probing
d = datum point 1
i = R (radius display)
e = datum point 2
j = R+- (radius comp.)
External
Operation
Via
RS-232-C/V.24
Data
Interface
Bateil2.pm6
27.03.2002, 12:09
68