beautypg.com

HEIDENHAIN ND 720 v.3 User Manual

Page 65

background image

65

Output

S

tructure

of

C

ompensation-Value

Table

Compensation-value table

Description:

.

X NR. 60 = ----------

X NR. 61 = ----------

X NR. 62 = ----------

X NR. 63 = ----------

*

Final character (*);

Compensation-value table ND 760, Z axis

Compensation-value table

Description:

*

Starting character (*);

ND-760 MM

Type of display unit; unit of measure (MM or IN);

AXIS =

2

Axis to be corrected, X = 0; Y = 1; Z = 2;

Z FCT. Z =

2

Axis causing the error, X = 0; Y = 1; Z = 2;

SPACING Z = 15

Spacing (range: 6 – 23)

DATUM Z = + 15.225

Datum point: +15.225 mm (value input)

Z NR. 00 = + 0.000

Compensation value 0 = 0.000 mm (compensation value 0 is always 0)

Z NR. 01 = - 0.030

Compensation values 1 – 10 are assigned values (value input)

Z NR. 02 = - 0.042

The axis is corrected from 15.225 mm to 342.905.

Z NR. 03 = - 0.008

Z NR. 04 = + 0.000

Z NR. 05 = + 0.009

Z NR. 06 = + 0.018

Z NR. 07 = + 0.025

Z NR. 08 = + 0.042

Z NR. 09 = + 0.051

Z NR. 10 = + 0.062

Z NR. 11 = ----------

Compensation values 11 – 63: no value entered (memory empty)

Z NR. 12 = ----------

.

Z NR. 63 = ----------

*

Final character (*);

Bateil2.pm6

27.03.2002, 12:09

65